This paper presents a contribution for air temperature measurement inside buildings. The objective is to show the influence due to long wave radiation in the measurement and that this effect can be minimized by a protection with a good radiant barrier. This protection can be made by using a PET bottle enveloped by aluminum paper, which has the effect of a barrier for long wave radiation. It was also possible to prove that the metallic globe of the globe thermometer can be replaced by a plastic globe material, without alteration on the results.

Downloads

Download data is not yet available.

Published

2008-12-29

How to Cite

BARBOSA, Miriam Jerônimo; LAMBERTS, Roberto; GUTHS, Saulo. Use of radiant barriers to reduce errors in temperature measurements inside buildings. Ambiente Construído, [S. l.], v. 8, n. 4, p. 117–136, 2008. Disponível em: https://seer.ufrgs.br/index.php/ambienteconstruido/article/view/6090. Acesso em: 3 aug. 2026.