Experimental appraisal for characterizing laboratorial and field performance parameters of pervious concrete pavement
Palabras clave:
concreto permeável, calçadas, ciclovias, parâmetros hidráulicos, colmataçãoResumen
Laboratorial tests with pervious concrete comprised porosity and hydraulic conductivity as well as mechanical parameters as compressive, indirect tensile and bending strengths besides assessing its static and dynamic elasticity moduli. Later, a pervious sidewalk area of 1.0 x 8.65 square meters was built in order to determine the variation of the infiltration rate along time; over such experimental sidewalk, impact deflection tests performed allowed to assess backcalculated moduli of the pervious concrete layer, resulting 33% to 13% lower than conventional concretes. A mechanistic analysis allowed to estimate the required thickness of concrete for heavy- and light-traffic areas. Tests disclosed no significant difference among the different concrete mixes, with 25% porosity and 0,1 cm/s permeability. Initial sidewalk infiltration rate of 0.5 cm/s dropped 50% four months after construction. It was verified that pervious concrete thicknesses for trucks and buses use are far higher than conventional concrete pavements.
Descargas
Descargas
Publicado
Cómo citar
Número
Sección
Licencia
Derechos de autor
Los autores de los artículos publicados por Ambiente Construido mantienen los derechos de autor de sus trabajos, licenciándolos bajo la licencia Creative Commons Attribution BY 4.0, la cual permite que los artículos sean reutilizados y distribuidos sin restricciones, siempre que la obra original sea debidamente citada.