Natural ventilation for office building retrofit in dense urban context under hot and humid climate

Autores/as

  • Marilia Ramalho Fontenelle Universidade Federal Fluminense
  • Leopoldo Eurico Gonçalves Bastos Universidade Federal do Rio de Janeiro
  • Sylvie Lorente Université de Toulouse, UPS, INSA

Palabras clave:

natural ventilation, urban canyon, thermal comfort, retrofit, adaptive thermal comfort

Resumen

Recent studies underline that simple and non-invasive retrofit solutions can recover natural ventilation potential in existing buildings under temperate climate. Nonetheless, the efficiency of these solutions in dense urban contexts under hot and humid climate remains unclear. This paper aims to evaluate the thermal comfort gains caused by natural ventilation when retrofitting an office building in downtown Rio de Janeiro. Computational Fluid Dynamics (CFD) and thermal simulations are carried out on Ansys CFX and Designbuilder to assess indoor air flow before and after retrofit. The diagnosis of the current scenario indicates that the surrounding buildings block a significant part of the wind flow, and occupants experience only a few hours of thermal comfort during the year, especially on lower floors. To increase indoor air flow, the fixed upper windows were transformed into pivot windows and kept open permanently. This measure increases the annual hours of thermal comfort by 0.5-35%, depending on the floor and the adaptive comfort model. These findings suggest that natural ventilation itself may not be sufficient to ensure occupants' comfort throughout the year under the investigated context.

Descargas

Los datos de descargas todavía no están disponibles.

Biografía del autor/a

Marilia Ramalho Fontenelle, Universidade Federal Fluminense

Professora Adjunta do Departamento de Arquitetura da Universidade Federal Fluminense

Leopoldo Eurico Gonçalves Bastos, Universidade Federal do Rio de Janeiro

Professor do Programa de Pós-graduação em Arquitetura (PROARQ), Universidade Federal do Rio de Janeiro

Sylvie Lorente, Université de Toulouse, UPS, INSA

Professoura Université de Toulouse, UPS, INSA

Laboratoire Matériaux et Durabilité des Constructions (LMDC)

Publicado

12.03.2021

Cómo citar

FONTENELLE, Marilia Ramalho; BASTOS, Leopoldo Eurico Gonçalves; LORENTE, Sylvie. Natural ventilation for office building retrofit in dense urban context under hot and humid climate. Ambiente Construído, [S. l.], v. 21, n. 2, p. 67–97, 2021. Disponível em: https://seer.ufrgs.br/index.php/ambienteconstruido/article/view/103510. Acesso em: 29 ago. 2025.

Número

Sección

Special Issue

Artículos similares

> >> 

También puede Iniciar una búsqueda de similitud avanzada para este artículo.