Microbiological characterization in specific environment in a university library in its composition and quality

Authors

DOI:

https://doi.org/10.19132/1808-5245253.373-389

Keywords:

Acervos bibliográficos – contaminação, Preservação documental, Micro-organismos

Abstract

Conservation and preservation of a library’s information material are necessary to extend the duration of their physical support and to ensure the integrity of historical, technical and scientific production for future generations. This study aims at characterizing the microorganisms in a specific environment in a university library that may cause damage to the collection and possible harm to the health of the users. It is an applied research which adopts experimental procedure and both qualitative and quantitative approaches. Samples were taken from the air and from 24 books. All samples were cultivated in plates with both selective and non-selective media for fungi and bacteria and incubated at 37 °C for 24h up to 48h (bacterial media) and for 4 up to 15 days (fungal media). Afterwards, colonies were enumerated, and their characteristics were evaluated. Conventional biochemical identification methods were performed. Results revealed molds, yeasts and bacteria and indicated numerical variations relating to the microorganism on book surface and in the air: although microbiota count in the air was significantly higher than that on the books, the later presented greater variety of microorganisms than the former.

Downloads

Download data is not yet available.

Author Biographies

Patricia de Oliveira Portela, Universidade Federal de Uberlândia

Bibliotecária do Setor de Referência da Universidade Federal de Uberlândia, Uberlândia, MG, mestre em Ciências Ambientais pela Unviersidade Brasil, Fernandópolis, SP

Dora Inés Kozusny-Andreani, Universidade Brasil, SP

Geneticista, mestra e doutora em Agronomia. Professora titular dos mestrados em Ciências Ambientais e em Bioengenharia. Vice coordenadora do curso do mestrado em Ciências Ambientais da  Universidade Brasil. 

References

BORREGO, S. et al. Estudio de la concentración microbiana en el aire de depósitos Del Archivo Nacional de Cuba. Augmdomus, La Plata, v. 1, p. 118-137, 2009.

BORREGO, S. et al. The quality of air at archives and the biodeterioration of photographs. International Biodeterioration and Biodegradation, Barking, v. 64, n. 2, p. 139-145, 2010.

BUENO, D. J.; SILVA, J. O.; OLIVER, G. Hongos ambientales en una biblioteca: un año de estudio. Anales de Documentación, Murcia, n. 6, p. 27-34, 2003.

CASSARES, N. C.; MOI, C. Como fazer conservação preventiva em arquivos e bibliotecas. São Paulo: Arquivo do Estado; Imprensa Oficial, 2000. (Projeto Como fazer, v. 5).

DALAL, L.; BHOWAL, M.; KALBENDE, S. Incidence of deteriorating fungi in the air inside the college libraries of Wardha city. Archives of Applied Science Research, Hyderabad, v. 3, n. 5, p. 479-485, 2011.

EDUARD, W. Fungal spores: a critical review of the toxicological and epidemiological evidence as a basis for occupational exposure limit setting. Critical Reviews in Toxicology, Boca Raton, v. 39, n. 10, p. 799–864, 2009.

FERREIRA, J. C.; PATINO, C. M. O que realmente significa o valor-p? Jornal Brasileiro de Pneumologia, Brasília, v. 41, n. 5, p. 485, Sept./Oct. 2015.

GALLO, F. Aerobiological research and problems in libraries. Aerobiologia, Bologna v. 9, p. 117-130, 1993.

HAYLEEYESUS, S. F.; MANAYE, A. M. Microbiological quality of indoor air in university libraries. Asian Pacific Journal of Tropical Biomedicine, Haikou, v. 4, (Suppl 1), S312-S317, 2014. Acesso em: 28 out. 2018.

HEMPEL, M. et al. Bacterial and fungal contamination in the library setting: a growing concern? Environmental Health Review, Ontario, v. 57, n. 1, p. 9-15, 2014.

KALWASIŃSKA, A.; BURKOWSKA, A.; WILK, I. Microbial air contamination in indoor environment of a university library. Annals of Agricultural and Environmental Medicine, Lublin, v. 19, n. 1, p. 25-29, 2012.

KARBOWSKA-BERENT, J. et al. Airborne and dust borne microorganisms in selected Polishlibraries and archives. Building and Environment, Kidlington, v. 46, n. 10, p. 1872-1879, 2011.

KORPI, A.; JÄRNBERG, J; PASANEN, A.-L. Microbial volatile organic compounds. Critical Reviews in Toxicology, Boca Raton, v. 39, n. 2, p. 139–193, 2009.

LABARRÈRE SARDUY, N. et al. Riesgos biológicos em ambientes confinados. Revista Cubana de Salud y Trabajo, Habana, v. 4, n. 1-2, p. 4-7, 2003.

LOURENÇO, M. J. L.; SAMPAIO, J. P. A deterioração microbiológica de espécies fotográficas com emulsão de gelatina: isolamento de microrganismos contaminantes de três colecções, Conservar Património, Lisboa, n. 2, p. 13-19, 2005. Disponível em: http://revista.arp.org.pt/pdf/2_2.pdf. Acesso em: 25 out. 2018.

MELLO, P. M. A. C.; SANTOS, M. J. V. C.; SILVA FILHO, J. T. (Ed.). Manual de conservação de acervos bibliográficos da UFRJ. Rio de Janeiro: UFRJ-SIBI, 2004. (Manual de procedimentos, 4).

MICHELUZ, Anna et al. The extreme environment of a library: Xerophilic fungi inhabiting indoor niches. International Biodeterioration & Biodegradation, Barking, v. 99, p. 1-7, 2015.

MILANESI, L. O que é biblioteca. São Paulo: Brasiliense, 1983.

MONTANARI, M. et al. Fungal biodeterioration of historical library materials stored in Compactus movable shelves. International Biodeterioration & Biodegradation, Barking, v. 75, p. 83-88, 2012.

NASCIMENTO, G. C. Avaliação da qualidade do ar em ambientes internos: biblioteca pública. 2011. Dissertação (Mestrado) – Universidade de São Paulo, São Paulo, 2011.

OSMAN, M. E. et al. Air microbial contamination and factors affecting its occurrence in certain book libraries in Egypt. Egyptian Journal of Botany, Cairo, v. 57, n. 3, p. 418-428, 2017.

PINZARI, F. et al. Electronic nose for the early detection of moulds in libraries and archives. Indoor and Built Environment, London, v. 13, n. 5, p. 387-395, 2004.

REIS-MENEZES, A. A. Fungos em bibliotecas: frequência dos gêneros em livros e elaboração de teste para avaliação da biorreceptividade em papéis. 2009. Tese (Doutorado) – Instituto de Biomédicas, Universidade de São Paulo, São Paulo, 2009.

REIS-MENEZES, A. A.; GAMBALE,W.; GIUDICE, M. C. A survey of fungal contamination on books in public libraries with mechanical and natural ventilation. Indoor and Built Environment, London, v. 20, n. 4, p. 393-399, 2011.

RENN, P. et al. The relation between fungal propagules in indoor air and home characteristics. Allergy, Copenhagen, v. 56, n. 5, p. 419-424, May 2001.

RIBEIRO, E. L. Fungos na biodeterioração de livros em ambientes bibliotecários nos últimos 35 anos (1977-2012). Revista Brasileira de Biblioteconomia e Documentação, São Paulo, v. 9, n. 1, p. 17-27, 2013.

RODRIGUES, M. A. Condições de trabalho e conforto em bibliotecas do ensino superior. 2009. Tese (Mestrado) – Universidade do Minho, Minho, 2009.

ROSS, M. A. et al. Association of asthma symptoms and severity with indoor bioaerosols. Allergy, Copenhagen, v. 55, n. 8, p. 705-711, 2000.

SHAMSIAN, A. et al. Fungal contaminations in historical manuscripts at Astan QudsMuseum Library, Mashhad, Iran. International Journal of Agriculture and Biology, Faisalabad, v. 8, n. 3, p. 420_422, 2006.

SCHWAB, C. J.; STRAUS, D. C. The roles of Penicillium and Aspergillus in sick building syndrome. Advances in Applied Microbiology, San Diego, v. 55, n. 8, p. 215-238, 2004.

SCOTT, G. Formação de mofo em ambientes tropicais: discussão. In: MENDES, M. et al. (Org.). Conservação: conceitos e práticas. Rio de Janeiro: UFRJ, 2001. p. 261-278.

SILVEIRA, D. T.; CÓRDOVA, F. P. A pesquisa científica. In: GERHARDT, Tatiana Engel; SILVEIRA, Denise Tolfo (Org.). Métodos de pesquisa. Porto Alegre: Ed. UFRGS, 2009. p. 31-42.

SKÓRA, J. et al. Assessment of microbiological contamination in the work environments of museums, archives and libraries. Aerobiologia, Bologna, v. 31, n. 3, p. 389–401, Sept. 2015.

STRYJAKOWSKA-SEKULSKA, M. et al. Microbiological quality of indoor air in university rooms. Polish Journal of Environmental Studies, Olsztyn, v. 16, n. 4, p. 623-632, 2007.

TOLOZA-MORENO, D. L.; LIZARAZO-FORERO, L. M.; BLANCO-VALBUENA, J. O. Concentración y composición microbiana en el ambiente de la Biblioteca Central Jorge Palacios Preciado de la Universidad Pedagógica y Tecnológica de Colombia, Tunja, Colombia. Actualidades Biologicas, Medellin, v. 34, n. 97, p. 241-252, 2012.

WANNER, H.-U. et al. Biological particles in indoor environments. Luxembourg: Commission of the European Communities, 1993. Report n. 12.

ZAR, J. H. Biostatistical analysis. 5th ed. Essex: Prentice Hall, 2009.

Published

2019-08-07

How to Cite

PORTELA, Patricia de Oliveira; KOZUSNY-ANDREANI, Dora Inés. Microbiological characterization in specific environment in a university library in its composition and quality. Em Questão, Porto Alegre, v. 25, n. 3, p. 373–389, 2019. DOI: 10.19132/1808-5245253.373-389. Disponível em: https://seer.ufrgs.br/index.php/EmQuestao/article/view/89846. Acesso em: 28 aug. 2025.

Issue

Section

Article

Similar Articles

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 > >> 

You may also start an advanced similarity search for this article.