Analytical Method Validation for the Detection of the Drug Sirolimus in Sugar-Coated Tablet using HPLC-DAD
DOI:
https://doi.org/10.22456/2527-2616.150632Keywords:
sirolimus, quality control, liquid chromatographyAbstract
Sirolimus (SRL) is an immunosuppressive macrolide widely used in transplant patients to prevent organ rejection. The development of an analytical method with adequate selectivity, sensitivity, and reliability is essential for its quality control and therapeutic monitoring. A validated analytical method for the quantification of SRL was developed using High-Performance Liquid Chromatography coupled with a Diode Array Detector (HPLC-DAD). The method demonstrated linearity for SRL in the concentration range of 10 to 80 μg.mL⁻¹ (r = 0.9999). Precision was confirmed with coefficients of variation below 2%, and accuracy showed recovery values close to 100%. The validated method was successfully applied to sugar-coated tablets, demonstrating its suitability for routine quality control. Therefore, the developed method can be reliably used for the quantitative analysis of Sirolimus in sugar-coated tablets.
Downloads
References
Moes DJAR, Guchelaar HJ, de Fijter JW. Sirolimus and everolimus in kidney transplantation. Drug Discovery Today. 2015;20(10):1243-1249. doi:10.1016/j.drudis.2015.05.006. DOI: https://doi.org/10.1016/j.drudis.2015.05.006
Holt DW, Lee T, Johnston A. Measurement of sirolimus in whole blood using high-performance liquid chromatography with ultraviolet detection. Clin Ther. 2000 Jan;22:B38–48. DOI: https://doi.org/10.1016/S0149-2918(00)89021-9
Jones K, Saadat-Lajevardi S, Lee T, Horwatt R, Hicks D, Johnston A, et al. An immunoassay for the measurement of sirolimus. Clin Ther. 2000 Jan;22:B49–61. DOI: https://doi.org/10.1016/S0149-2918(00)89022-0
Pieri M, Miraglia N, Castiglia L, Genovese G, Basilicata P, Simonelli A, et al. Determination of rapamycin: quantification of the sodiated species by an ion trap mass spectrometer as an alternative to the ammoniated complex analysis by triple quadrupole. Rapid Communications in Mass Spectrometry. 2005 Nov 15;19(21):3042–50. DOI: https://doi.org/10.1002/rcm.2168
Rao MVB, Nagendrakumar AVD. Development and Validation of RP-HPLC Method for the Estimation of Sirolimus in Formulation and Serum [Internet]. IDC Online; [date unknown] [cited 2025 Sep 29]. Available from:https://idc-online.com/technical_references/pdfs/chemical_engineering/DEVELOPMENT%20AND%20VALIDATION.pdf
Brazil. National Health Surveillance Agency (ANVISA). Resolution RDC No. 166, of July 24, 2017. Provides for the validation of analytical methods and other provisions. Official Gazette of the Federal Government of Brazil. July 25, 2017; Sec. 1:87.
Il’ichev YV, Alquier L, Maryanoff CA. Degradation of rapamycin and its ring-opened isomer: role of base catalysis. Arkivoc. 2007;2007(12):110–31. DOI: https://doi.org/10.3998/ark.5550190.0008.c09
Asrani SK, Leise MD, West CP, Murad HM, Pedersen RA, Erwin PJ, et al. Use of sirolimus in liver transplant recipients with renal insufficiency: a systematic review and meta-analysis. Hepatology. 2010;52(4):1360–70. DOI: https://doi.org/10.1002/hep.23835
Augustine JJ, Bodziak KA, Hricik DE. Use of sirolimus in solid organ transplantation. Drugs. 2007;67(3):369–91. DOI: https://doi.org/10.2165/00003495-200767030-00004
Keogh A, Richardson M, Ruygrok P, Spratt P, Galbraith A, O’Driscoll G, et al. Sirolimus in de novo heart transplant recipients reduces acute rejection and prevents coronary artery disease at 2 years. Circulation. 2004;110(17):2694–700 DOI: https://doi.org/10.1161/01.CIR.0000136812.90177.94
Yanik EL, Siddiqui K, Engels EA. Sirolimus effects on cancer incidence after kidney transplantation: a meta-analysis. Cancer Med. 2015;4(9):1448–59 DOI: https://doi.org/10.1002/cam4.487
Islambulchilar Z, Ghanbarzadeh S, Emami S, Valizadeh H, Zakeri-Milani P. Development and validation of an HPLC method for the analysis of sirolimus in drug products. Adv Pharm Bull. 2012;2(2):135–9.
Campos MST, Fialho SL, Pereira BG, Yoshida MI, Oliveira MA. Kinetics studies of the degradation of sirolimus in solid state and in liquid medium. J Therm Anal Calorim. 2017;130(3):1653–61. DOI: https://doi.org/10.1007/s10973-017-6580-1
Peris-Vicente J, Esteve-Romero J, Carda-Broch S. Validation of analytical methods based on chromatographic techniques: an overview. In: Poole CF, editor. Analytical separation science. Weinheim (Germany): Wiley; 2015. p. 1757–808. DOI: https://doi.org/10.1002/9783527678129.assep064
Downloads
Published
Versions
- 30-03-2026 (2)
- 19-12-2025 (1)
How to Cite
Issue
Section
License
Copyright (c) 2025 Drug Analytical Research

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
The Copyright holder of manuscripts published is Drug Analytical Research. Authors who publish with this journal are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
Licensing:
Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License
Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles, or use them for any other lawful purpose, without asking prior permission from the publisher or the author.