INFLUENCE OF DISINFECTANTS ON THE DIMENSIONAL STABILITY OF ALGINATE IMPRESSIONS
DOI:
https://doi.org/10.22456/2177-0018.146567Keywords:
Disinfection, Alginates, Physical phenomenaAbstract
Objective: to evaluate the influence of different disinfectants on the dimensional stability of an alginate (Orthoprint/Zhermack). Materials and Methods: Seventy specimens were constructed with the impression material, from a metal matrix, and distributed into the following groups (n=10): Control - washing with water (CTL); use of 1% sodium hypochlorite (HCS); use of 0.2% peracetic acid (APE); use of 0.5% hydrogen peroxide (PH1/PH2); use of quaternary ammonium + polyhexanide (QP1/QP2). From a metallic matrix and following the specification nº 19 of the ADA and the instructions of the manufacturers, 70 alginate specimens were obtained, distributed among the groups (n = 10). To analyze the dimensional change (AD%), the distance between specific points of the specimens was evaluated using a stereomicroscope, with 1.65 times magnification and compared to the matrix. The data obtained were transformed into percentages using a mathematical formula and submitted to the Student's t-test and analysis of variance, and means were compared using Tukey's test. Results: Significant dimensional changes were observed in groups PH2 (AD% = + 0.58, p = 0.008) and QP2 (AD% = + 0.34 p = 0.039) when compared with the value of the metallic matrix. discussion: Simplified disinfection products can be used on alginate without causing significant dimensional changes, depending on the composition of the disinfectant. Conclusion: Most of the disinfectants (HCS, APE, PH1, and QP1) did not cause significant dimensional changes in the alginate, with the exception of PH2 and QP2.
Downloads
References
D'Mello M, A R, A C, G P. The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials. J Oral Sci. 2008;50(4).
Souza FBD, Silva ARS, Torres GRS, et al. Infection control practices in dental healthcare settings for the corona virus disease 2019 (COVID-19) pandemic. J Dent Health Oral Disord Ther. 2020;11(4):102-106.
Hemalatha R, Ganapathy D. Disinfection of dental impression – a current overview. J Pharm Sci Res. 2016;8(7):661-4.
Carvalhal CI, Mello JA, Sobrinho LC, Correr AB, Sinhoreti MA. Dimensional change of elastomeric materials after immersion in disinfectant solutions for different times. J Contemp Dent Pract. 2011;12(4).
Ginjupalli K, Alla RK, Tellapragada C, Gupta L, Perampalli NU. Antimicrobial activity and properties of irreversible hydrocolloid impression materials incorporated with silver nanoparticles. J Prosthet Dent. 2016;115(6).
Guiraldo RD, Borsato TT, Berger SB, et al. Surface detail reproduction and dimensional accuracy of stone models: influence of disinfectant solutions and alginate impression materials. Braz Dent J. 2012;23:417-21.
Guiraldo RD, Moreti AF, Martinelli J, Berger SB, Meneghel LL, Caixeta RV, et al. Influence of alginate impression materials and storage time on surface detail reproduction and dimensional accuracy of stone models. Acta Odontol Latinoam. 2015;28(2).
Demajo JK, Cassar V, Farrugia C, Millan-Sango D, Sammut C, Valdramidis V, et al. Effectiveness of disinfectants on antimicrobial and physical properties of dental impression materials. Int J Prosthodont. 2016;29(1):63-7.
Babiker GH, Khalifa N, Alhajj MN. Dimensional accuracy of alginate impressions using different methods of disinfection with varying concentrations. Compend Contin Educ Dent. 2018;39(1).
Council on Dental Materials and Devices. Council adopts American Dental Association Specification No. 18 (alginate impression material). J Am Dent Assoc. 1968;77(6).
Revised American Dental Association Specification No. 19 for Non-aqueous, Elastomeric Dental Impression Materials. J Am Dent Assoc. 1977;94(4).
Porrelli D, Berton F, Reboa A, Cattaneo R. Evaluating the stability of extended-pour alginate impression materials by using an optical scanning and digital method. J Prosthet Dent. 2021;125(1):189.e1-189.e7.
Ulgey M. Importance of disinfection time and procedure with different alginate impression products to reduce dimensional instability. Niger J Clin Pract. 2020;23(3):284.
Amin WM, Al-Ali MH, Al Tarawneh SK, Taha ST, Saleh MW, Ereifij N. The effects of disinfectants on dimensional accuracy and surface quality of impression materials and gypsum casts. J Clin Med Res. 2009;1(2):81.
Azevedo MJ, Correia I, Portela A, Sampaio-Maia B. A simple and effective method for addition silicone impression disinfection. J Adv Prosthodont. 2019;11(3).
Taylor RL, Wright PS, Maryan C. Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum cast. Dent Mater. 2002;18(2):103-10.
Queiroz DA, Melo PM, Nogueira AC, Faria F, Tabchoury MR, Santos-Cruz LR. Influence of disinfection with peracetic acid and hypochlorite in dimensional alterations of casts obtained from addition silicone and polyether impressions. J Contemp Dent Pract. 2013;14(6).
3M Company. Ficha de informações de segurança de produtos químicos: Scotch Brite Limpador Peróxido; 2020.
Holmberg K. Organic reactions in microemulsions. Curr Opin Colloid Interface Sci. 2003;8(2):187-96.
Diversey Inc. Oxivir Brochure: powered by accelerated hydrogen peroxide; 2018.
Oliveira JA, organizador. Germi Rio: solução à base de mistura de quaternários de amônio, cloreto de didecildimetilamônio e cloridrato de polihexametileno biguanida (PHMB). São Paulo: Rioquímica; 2021.
Trivedi R, Sangur R, Bathala LR, Srivastava S, Madhav S, Chaubey P. Evaluation of efficacy of Aloe Vera as a Disinfectant by Immersion and Spray methods on Irreversible Hydrocolloid Impression Material and its Effect on the Dimensional Stability of Resultant Gypsum Cast–An in Vitro Study. J Med Life. 2019;12(4):395.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Patrícia Tereza Lopes de Souza, Bárbara Lucena Silveira, Tulio Marcos dos Santos Silva, Roberta Bagnatori Ribeiro Bagnara, Fabio Barbosa de Souza

This work is licensed under a Creative Commons Attribution 4.0 International License.
All articles published in this journal adhere to Creative Commons License Attributions 4.0 (CC BY 4.0), and its use must be ruled by its licensed means. Authors are allowed to agree to additional and separate contracts for the non-exclusive distribution of the article published in this journal, such as publishing in an institutional repository, as long as the article has a recognition of authorship and first publication in this journal.