Effects of JPEG compression in quantitative digital radiographic subtraction of simulated bone loss
DOI:
https://doi.org/10.22456/2177-0018.103372Keywords:
Radiography dental, Radiographic image enhancement, Alveolar bone lossAbstract
In order to evaluate the effect of JPEG compression in quantitative digital radiographic subtraction, 12 periapical x-rays of the lower molar region were digitized at 300 dpi and 8 bits, duplicated and saved as two subsets of images labelled 'A' and 'B' using the JPEG level 12 format. Areas simulating bone loss (1%, 3% and 5%) were digitally demarcated in the 'B' subset of images. All the images were reproduced digitally and saved using JPEG 10, 8, 6 and 4 compressions. For each compression tested, image subtraction was pezformd and the mean density and standard deviation of the gray levels was measured. The quantitative digital radiographic subtraction, using the Image Tool software application, was not affected by compression JPEG level 10. Although levels 8 and 6 allow the detection of changes in density, they tend to result in overestimation of the bone loss.Downloads
Download data is not yet available.
Downloads
Published
2003-06-01
How to Cite
Winck Mahl, C. E., Gegler, A., Porto Alegre Braga, C., Xavier Machado, L., & Fontanella, V. (2003). Effects of JPEG compression in quantitative digital radiographic subtraction of simulated bone loss. Revista Da Faculdade De Odontologia De Porto Alegre, 44(2), 31–33. https://doi.org/10.22456/2177-0018.103372
Issue
Section
Original articles
License
All articles published in this journal adhere to Creative Commons License Attributions 4.0 (CC BY 4.0), and its use must be ruled by its licensed means. Authors are allowed to agree to additional and separate contracts for the non-exclusive distribution of the article published in this journal, such as publishing in an institutional repository, as long as the article has a recognition of authorship and first publication in this journal.