Sciatic Nerve Injection Palsy in a Dog: Electrodiagnostic Testing and Microsurgical Treatment

Authors

  • Ana Carolina Mortari Faculty of Agronomy and Veterinary Medicine, Universidade de Brasília (UnB), Brasília, DF, Brazil.
  • Juliany Gomes Quitzan Department of Veterinary Surgery and Anesthesiology School of Veterinary Medicine and Animal Science, Universidade Estadual Paulista (UNESP), Botucatu, SP, Brazil.
  • Claudia Valéria Seullner Brandão Department of Veterinary Surgery and Anesthesiology School of Veterinary Medicine and Animal Science, Universidade Estadual Paulista (UNESP), Botucatu, SP, Brazil.
  • Sheila Canevese Rahal Department of Veterinary Surgery and Anesthesiology School of Veterinary Medicine and Animal Science, Universidade Estadual Paulista (UNESP), Botucatu, SP, Brazil.

DOI:

https://doi.org/10.22456/1679-9216.86738

Abstract

Background: Iatrogenic damage to the ischiatic nerve is considered uncommon and may cause dysfunction with variable clinical signs dependent on type and severity of injury. Due to important role of this nerve in locomotion and weightbearing limb, a poor prognosis for recovery may be observed in many cases. Electromyography analysis may suggest the neuroanatomic localization, diagnosis information, and severity of lesion to determine better therapeutic intervention. Therefore, the aim of this report is to describe the possible cause, diagnosis and treatment of a postinjection ischiatic nerve injury in a dog with complete recovery.
Case: A 3-year-old neutered male dachshund dog was referred to the Veterinary Hospital due to inability to weight support in the right hind limb after diminazene diaceturate intramuscular injection. The gait evaluation showed dropped-hock and knuckling into the digits of the right hind limb and neurologic examination revealed moderate muscle atrophy below to
femorotibial joint of the right hind limb with sensory analgesia (superficial and deep) on the lateral, dorsal, and plantar surfaces, absent patellar reflex, and proprioceptive deficit. Electrophysiologic testing was done under general anesthesia in a 2-channel Nicolet Compass Meridian apparatus. Absence of compound muscle action potentials after right fibular and tibial nerve stimulations, and abnormal spontaneous activity in cranial tibial, gastrocnemius and deep digital extensor muscles were observed. A diagnosis of moderate/severe axonotmesis of sciatic nerve was achieved. Under microscope magnification, all adherent adjacent tissue and epineural sheat were removed. Due this, a small epineural window was created. On neurological examination performed 30 days after surgery, complete recovery of sensitivity of the right hind limb, and normal proprioception were observed. The muscle atrophy was also noted to have improved.
Discussion: The ischiatic nerve mechanisms of injury include direct needle trauma, the drug or vehicle used for injection, or secondary constriction by scar, factors that may be associated to damage nerve observed in the present case. During a sciatic nerve injection, the combination of intrafascicular placement of a needle and high-pressure injection may cause severe fascicular damage and persistent neurologic deficits. In the present case, damage to the nerve probably was not caused by
the injection needle, but due to injection agent. Chemical irritation or toxic reaction to the agent may cause different degrees of nerve injury. The electrophysiologic testing is an important tool for determining alteration of function and integrity of the axonal motor unit. In the present report, the electrophysiologic testing showed denervation potentials in the muscles
innervated by the sciatic nerve (positive waves and fibrillation potentials), and the absence of compound muscle action potentials was indicative of severe axonal damage of the right ischiatic nerve. In human patients with postinjection ischiatic nerve injury, early surgical treatment with neurolysis or resection and anastomosis are the procedures recommended. In the present report, external neurolysis and epineural window were used showing excellent functional results. The epineural window was performed due to adherence of tissue and scar surrounding the nerve, permitting neural decompression.
Keywords: axonotmesis, neurophysiology, neurolysis, dogs.

Downloads

Download data is not yet available.

References

Chambers J.N. & Hardie E.M. 1986. Localization and management of sciatic nerve injury due to ischial or acetabular fracture. Journal American Animal Hospital Association. 22: 539-544.

DeLahunta A., Glass E. & Kent M. 2015. Lower Motor Neuron: Spinal Nerve, General Somatic Efferent System. In: De Lahunta A., Glass E. & Kent M. (Eds). Veterinary Neuroanatomy and Clinical Neurology. 4th edn. Philadelphia:Saunders, pp.102-161.

Dumitru D., Zwarts M. & Amato A.A. 2002. Peripheral nervous system’s reaction to injury. In: Dumitru D., Amato A.A. & Zwarts M. (Eds). Electrodiagnostic Medicine. 2nd edn. Philadelphia: Hanley & Belfus, pp.115-158.

Esquenazi Y., Park S.H., Kline D.G. & Kim D.H. 2016. Surgical management and outcome of iatrogenic radial nerve injection injuries. Clinical Neurology and Neurosurgery. 142: 98-103.

Forterre F., Tomek A., Rytz U., Brunnberg L., Jaggy A. & Spreng D. 2007. Iatrogenic sciatic nerve injury in eighteen dogs and nine cats (1997-2006). Veterinary Surgery. 36: 464-471.

Gemmmil T. & Mckee M. 2012. Monoparesis and neurological causes of lameness. In: Platt S. & Garosi L. (Eds). Small Animal Neurological Emergencies. Boca Raton: Taylor & Francis Group, pp.299-316.

Gentili F., Hudson A., Kline D. & Hunter D. 1980. Early changes following injection injury of peripheral nerves. Canadian Journal of Surgery. 23(2): 177-182.

Gilmore D.R. 1984. Sciatic nerve injury in twenty-nine dogs. Journal American Animal Hospital Association. 20(3):403-407.

Hadzic A., Dilberovic F., Shah S., Kulenovic A., Kapur E., Zaciragic A., Cosovic E., Vuckovic I., Divanovic K.A., Mornjakovic Z., Thys D.M. & Santos A.C. 2004. Combination of intraneural injection and high injection pressure

leads to fascicular injury and neurologic deficits in dogs. Regional Anesthesia and Pain Medicine. 29(5): 417-423.

Jacobson A. & Schrader S.C. 1987. Peripheral nerve injury associated with fracture or fracture-dislocation of the pelvis in dogs and cats: 34 cases (1978–1982). Journal American Veterinary Medical Association. 190(5): 569-572.

Joubert K.E., Kettner F., Lobetti R.G. & Miller D.M. 2003. The effects of diminazene aceturate on systemic blood pressure in clinically healthy adult dogs. Journal of the South African Veterinary Association. 74(3): 69-71.

Kimura J. 2013. Anatomy and physiology of the peripheral nerve and type of nerve pathology. In: Kimura J. (Ed).Electrodiagnosis in Diseases of Nerve and Muscle: Principles and Practice. 4th edn. New York: Oxford UniversityPress, pp.49-73.

Lin M.Y. & Huang H.P. 2010. Use of a doxycycline-enrofloxacin-metronidazole combination with/without diminazene diaceturate to treat naturally occurring canine babesiosis caused by Babesia gibsoni. Acta Veterinaria Scandinavica.52(1): 27.

Miller D.M., Swan G.E. & Lobetti R.G. 2005. The pharmacokinetics of diminazene aceturate after intramuscular administration in healthy dogs. Journal of the South African Veterinary Association. 76(3): 146-150.

Preston D.C. & Shapiro B.E. 2005. Basic electromyography: analysis of spontaneous activity. In: Preston D.C. & Shapiro B.E. (Eds). Electromyography and Neuromuscular Disorders. Clinical -Electrophysiologic Correlations. 2nd edn. Philadelphia: Elsevier, pp.199-214.

Senes F.M., Campus R., Becchetti F. & Catena N. 2009. Sciatic nerve injection palsy in the child: early microsurgical treatment and long-term results. Microsurgery. 29(6): 443-448.

Topuz K., Kutlay M., Simsek H., Atabey C., Demircan M. & Senol G.M. 2011. Early surgical treatment protocol for sciatic nerve injury due to injection: a retrospective study. British Journal of Neurosurgery. 25(4): 509-515.

Villarejo F.J. & Pascual A.M. 1993. Injection injury of the sciatic nerve (370 cases). Child’s nervous system. 9(4):229-232.

Published

2018-01-01

How to Cite

Mortari, A. C., Quitzan, J. G., Brandão, C. V. S., & Rahal, S. C. (2018). Sciatic Nerve Injection Palsy in a Dog: Electrodiagnostic Testing and Microsurgical Treatment. Acta Scientiae Veterinariae, 46, 4. https://doi.org/10.22456/1679-9216.86738

Most read articles by the same author(s)