Femoral Orthopedic Implants in Dogs with Titanium - Mechanical Evaluation
DOI:
https://doi.org/10.22456/1679-9216.116108Abstract
ABSTRACT
Background: Orthopedic implants are commonly used for different types of surgical procedures to gain optimal function and to provide stability to both bones and tendon structures. When inserting these implants, the characteristics of the material are important for surgical success, and the ideal implant must be biocompatible and nonallergenic. However, when molding an implant to the bone structure, its resistance can change significantly. Implants can be temporary or permanent in the body, and metal possesses properties that make it acceptable for bone repair. In biomedical implants, 2 types are most common, commercially pure (CP)-Ti and Ti-6A1-4V. They both provide stable fixation and low risk of loosening. Implants made with the same material and composition can perform differently if the material has been altered by processing techniques for different scenarios. Stress, strain and elastic modulus are the primary metrics used in the description of implant materials. They can be calculated based on mechanical tests of specimens with defined geometry, most commonly tensile, bending and torsional tests. In order to better evaluate those changes, we compared the mechanical characteristics of titanium bone plates, before and after they were molded to the bone, to verify and quantify the loss of stiffness and resistance after molding the plate.
Materials, Methods & Results: The study was prospective. Orthopedic implant made of commercially pure titanium (CP-Ti) were divided into 2 groups, one group without plate molding and the other with plate molding to a dog femora bone. Thirty-six plates of different sizes (5.0, 6.5, 8.0, 9.0, 10.0 and 11.0-mm diameter) were divided into 6 groups containing 6 plates of each size and submitted to the 4-point flexion test of resistance, using a piece of dog femur (weights of 5, 10, 15, 20 and 25 kg) as the bone in which the molding was performed. The evaluations were tabulated and analyzed using the program GraphPad Prism version 5.0. Corrections of the normal distribution curve were made using the Bartlett test. After the corrections, one-way analysis of variance (ANOVA) was performed with P < 0.05. Assessments were made within the group and between groups. Subsequently, the Newman-Keuls test was performed, adopting P < 0.05. For analyses in 2 groups, Student's t-test was performed as a post-test, also with P < 0.05. When the plates were compared between equal sizes of groups 1 and 2, the non-molded plate group (G1) obtained the best results in the flexural stiffness and structural flexion tests. However, in the flexural resistance test, most plates obtained similar results and the plates with diameters of 8 mm, 9 mm and 10 mm of the molded plate group (G2) obtained the best results.
Discussion: Our results show that the implants had adequate mechanical characteristics, but the unmolded plates had greater flexural and structural stiffness than the molded plates. This difference was significant, thus demonstrating a large loss of stiffness in relation to the original conformation. However, when we tested the flexural resistance, no significant differences were observed, and although without significant statistical changes, there was an increase in the resistance of the plate with the new conformation obtained by molding. In the results of the mechanical tests, we observed that after the molding, the implants gained greater resistance, although the difference was not statistically significant. This suggests that the architecture of the implants should have slight curvature in the medial direction of the bone, since this would lead to a better adaptation to the anatomy of the bone, and possibly greater resistance, as indicated by the new configuration after molding.
Keywords: bone implants, titanium, orthopedic implants, femur, dogs.
Downloads
References
Dux K.E. 2019. Implantable Materials Update. Clinics in Podiatric Medicine and Surgery. 36(4): 535-542.
Hoffmeier K.L., Hofmann G.O. & Mückley T. 2011. Choosing a proper working length can improve the lifespan of locked plates. A biomechanical study. Clinical Biomechanics (Bristol, Avon). 26(4): 405-409.
Huiskes R., Weinans H. & van Rietbergen B. 1992. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clinical Orthopaedics and Related Research. (274): 124-134.
Jiang N., Guo Z., Sun D., Ay B., Li Y., Yang Y., Tan P., Zhang L. & Zhu S. 2019. Exploring the mechanism behind improved osteointegration of phosphorylated titanium implants with hierarchically structured topography. Colloids and Surfaces B: Biointerfaces. (184): 110-520.
Kaczmarek J., Bartkowiak T., Schuenemann R., Paczos P., Gapinski B., Bogisch S. & Unger M. 2020. Mechanical Performance of a Polyaxial Locking Plate and the Influence of Screw Angulation in a Fracture Gap Model. Veterinary and Comparative Orthopaedics and Traumatology. 33(1): 36-44.
Kaur M. & Singh K. 2019. Review on titanium and titanium-based alloys as biomaterials for orthopaedic applications. Materials Science and Engineering C, Materials for Biological Applications. (102): 844-862.
Park K.H., Oh C.W., Park I.H., Kim J.W., Lee J.H. & Kim H.J. 2019. Additional fixation of medial plate over the unstable lateral locked plating of distal femur fractures: A biomechanical study. Injury. 50(10): 1593-1598.
Roe S. 2020. Biomechanics of Fracture Fixation. Veterinary Clinics North America: Small Animal Practice. 50(1): 1-15.
Yamada H., Yoshihara Y., Henmi O., Morita M., Shiromoto Y., Kawano T., Kanaji A., Ando K., Nakagawa M., Kosaki N. & Fukaya E. 2009. Cementless total hip replacement: past, present, and future. Journal of Orthopaedic Science. 14(2): 228-241.
Zdero R. & Bougherara H. 2010. Orthopaedic biomechanics: a practical approach to combining mechanical testing and finite element analysis. In: Moratal D. (Ed). Finite Element Analysis. Shangai: Intech, pp.307-332.
Zhang W.D., Liu Y., Wu H., Song M., Zhang T.Y., Lan X.D. & Yao T.H. 2015. Elastic modulus of phases in Ti–Mo alloys. Materials Characterization. (106): 302-307.
Published
How to Cite
Issue
Section
License
This journal provides open access to all of its content on the principle that making research freely available to the public supports a greater global exchange of knowledge. Such access is associated with increased readership and increased citation of an author's work. For more information on this approach, see the Public Knowledge Project and Directory of Open Access Journals.
We define open access journals as journals that use a funding model that does not charge readers or their institutions for access. From the BOAI definition of "open access" we take the right of users to "read, download, copy, distribute, print, search, or link to the full texts of these articles" as mandatory for a journal to be included in the directory.