Ventilated cladding systems: structural and drainability performance criteria

Autores

  • Luiz Fernando Batista da Silva Instituto de Pesquisas Tecnológicas do Estado de São Paulo - IPT
  • Ercio Thomaz Instituto de Pesquisas Tecnológicas do Estado de São Paulo - IPT
  • Luciana Alves de Oliveira Instituto de Pesquisas Tecnológicas do Estado de São Paulo - IPT

Palavras-chave:

Ventilated Cladding Systems. Rainscreen claddings. Building Performance Criteria. Moisture safety. Test Methods.

Resumo

Cladding systems have significant effect on the performance and durability of building façades, contributing to the building watertightness, property valuation, aesthetic finishing, and decoration. Non-adherent cladding, also named rainscreen cladding or ventilated cladding, is currently used in residential and commercial buildings, new constructions, or retrofit operations, and it is considered an efficient measure to improve the moisture safety of building envelopes. Therefore, the absence of Brazilian normalization to ventilated cladding systems is one of the difficulties limiting its increased local application. In Brazil, a technical standard, NBR 15575, parts 1–6, (2013), establish the general performance requirements and test methods to evaluate residential building systems including structure, wall, floor, coverage, and hydraulic installation. However, this standard cannot be integrally applied to the cladding systems because it was developed considering the vertical wall system as a whole. In this study, we propose the criteria and test methods for assessing ventilated cladding systems while taking into account the structural safety (wind loads resistance, hard and soft impact resistance) and drainability requirements. The following activities are performed: literature review, practical case study, and tests on prototypes for validation of the proposal. The tests allow verification of the feasibility of the criteria and tests methods proposed. In addition, the proposal makes it possible to guide design, construction, and maintenance needs, thereby inducing the growth of this technology in Brazil.

Downloads

Não há dados estatísticos.

Biografia do Autor

Luiz Fernando Batista da Silva, Instituto de Pesquisas Tecnológicas do Estado de São Paulo - IPT

Centro Tecnológico do Ambiente Construido - CETAC

Ercio Thomaz, Instituto de Pesquisas Tecnológicas do Estado de São Paulo - IPT

Centro Tecnológico do Ambiente Construido - CETAC

Luciana Alves de Oliveira, Instituto de Pesquisas Tecnológicas do Estado de São Paulo - IPT

Pesquisadora do IPT, doutora pela Escola Politecnica em construcao civil

Publicado

11.07.2018

Como Citar

SILVA, L. F. B. da; THOMAZ, E.; OLIVEIRA, L. A. de. Ventilated cladding systems: structural and drainability performance criteria. Ambiente Construído, [S. l.], v. 18, n. 3, p. 341–358, 2018. Disponível em: https://seer.ufrgs.br/index.php/ambienteconstruido/article/view/72500. Acesso em: 16 abr. 2024.